RNA Extraction

α+ Solution™ Tissue Total RNA Mini Kit

Catalog #: APTRK004 / APTRK050 / APTRK100

Manufacturer: ALPHAGEN

Size: 4 preps50 preps100 preps

Price: on inquiry

Principle
mini spin column (silica matrix)
Sample size
Please see Table. Sample amount and Yield.
Operation time
30 ~ 60 minutes
Storage
Store at room temperature (15~ 25 ℃) for 2 year.

RNA Extraction

Ordering information

APTRK0044 preps (sample)
APTRK05050 preps
APTRK100100 preps

Storage: Store at room temperature (15~ 25 ℃) for 2 year.

Component

APTRK 004
(4 preps)
APTRK 050
(50 preps)
APTRK 100
(100 preps)
RB Buffer 1.5 ml x 2 25 ml 45 ml
Wash Buffer 1 1.5 ml x 2 30 ml 60 ml
Wash Buffer 2 * (concentrate) 1.5 ml 15 ml 35 ml
RNase-free Water 0.5 ml 6 ml 6 ml
Filter Column 4 pcs 50 pcs 100 pcs
RB Mini Column 4 pcs 50 pcs 100 pcs
Collection Tube 8 pcs 100 pcs 200 pcs
Elution Tube 4 pcs 50 pcs 100 pcs
User Manual 1 1 1

Brief Prodecure

Specification

※ Principle : mini spin column (silica matrix)

※ Sample size : Please see Table. Sample amount and Yield.

※ Operation time : 30 ~ 60 minutes

※ Binding capacity : up to 100 μg total RNA/ column

※ Expected yield : Please see Table. Sample amount and Yield.

※ Column applicability : centrifugation and vaccum

※ Minimum elution volume : 40 μl

Important Notes :

※ Make sure everything is RNase-free when handling RNA.

※ Buffers provided in this system contain irritants. Wear gloves and lab coat when handling these buffers.

※ Caution: ß-mercaptoethanol is hazardous to human health. perform the procedures involving RB Buffer or PRB Buffer in a chemical fume hood.

※ Add required volume of RNase-free ethanol (96~100%) to Wash Buffer 2 when first use.

※ Dilute RNase-free DNase 1 in reaction buffer (1M NaCl, 10 mM MnCl2, 20 mM Tris-HCl, pH 7.0 at 25ºC) to final conc. = 0.5 U/μl.

Trouble shooting

Problems

Possible reasons

Solutions

Low yield


Too much starting sample used may cause insufficient lysis and homogenization.

In Step.1 sample preparation, reduce the amount of starting sample or increase the volume of RB Buffer.

Incorrect RNA elution step.

Ensure that Elution Buffer was added and absorbed to the center of the RB Column matrix.

Ethanol carryover.

Ensure that centrifuge at ≥ 8000 x g (≥ 10,000 rpm) for 3 min to dry the RB column membrane in Step.6 Dry Column.

Incorrect preparation of Wash 2 Buffer.

Ensure that the correct volume of ethanol (96 ~ 100 %) was added to Wash 2 Buffer before use.

RNA degraded

Age of Sample.

Please use the fresh sample.

Residual DNA

DNA Contamination.

Please follow the Optional step to remove DNA.

RNA does not perform well in downstream experiments

Salt carryover during elution.

Ensure that Wash 2 Buffer is at room temperature (15–25°C).

Ethanol carryover.

Perform the step.6 in the protocol(centrifuge at ≥ 8000 x g or ≥ 10,000 rpm) to remove all traces of ethanol before eluting.

Documents

View this product on the manufacturer website (ALPHAGEN) ↗

Request a quotation

Fill in the form and the Envision Sciplus team will reply with a quotation and delivery time.

Product α+ Solution™ Tissue Total RNA Mini Kit Catalog #: APTRK004 / APTRK050 / APTRK100