Pipettes

Pipette, 1-10 μL, Pink

Catalog #: SPIP-10

Manufacturer: Servicebio

Size: 1-10 μL

Price: on inquiry

Colour
Pink
Volume range
1-10 μL

Product information

Catalog #SPIP-10
Sizepc (1-10 μL)
Volume range1-10 μL
ColourPink

Accuracy

Allowable Volume Error: 10±0.12 μL(±1.2%) | 5±0.12 μL(±2.4%) | 1±0.12 μL(±12%)

Repeatability Error: 10 μL(≤0.80%) | 5 μL(≤1.60%) | 1 μL(≤8.00%)

Product Introduction:

A pipette is a device used to transfer liquid quantitatively. In the research of analytical testing, a pipette is generally used to transfer small or microliter amounts of liquid.

There are 7 colors to choose from, and exclusive lucky colors can be customized!

SPIP-10 Pipette Compatibility Chart
PipetteSpec.NameCat. No.
SPIP-1010 μL10μL Pipette Tip (Sterilized, DNase & RNase Free)TP-10-C
10μL Pipette Tip (Sterilized, DNase & RNase Free)
TP-10-J
10μL Pipette Tip (Sterile,RNase & DNase Free, Transparent)P-10-J
10 μL Extended10μL Extended Pipette Tip (Sterilized, DNase & RNase Free)TP-10P-C
10μL Extended Pipette Tip (Sterile,RNase & DNase Free)TP-10P-J
10μL with Filter10μL Filter Tip (Sterile,RNase & DNase Free)TP-10-C-F
10μL Extended with Filter10μL Extended Filter Tip (Sterile,RNase & DNase Free)TP-10P-C-F

Product Features:

1. 17 volume ranges available, including 6 eight-channel models; color-coded for easy identification; available in both single-channel and 8-channel options

2. Lightweight spring design for exceptionally low plunger force and comfortable operation

3. Optimized with Servicebio pipette tips to ensure excellent airtightness and accurate liquid handling

4. Compatible with most standard pipette tips on the market

5. CE certified, compliant with ISO 8655-2:2022 international standard

Parameter Comparasion

Item NameCat.No.Nominal VolumeVolume RangeIncrement
Single Channel PipetteSPIP-2.52.5 μL0.1-2.5 μL0.05 μL
SPIP-1010 μL1-10 μL0.1 μL
SPIP-20L20 μL2-20 μL (For 10 μL, 10 μL extended tips)0.1 μL
SPIP-2020 μL2-20 μL (For 200 μL tips)0.1 μL
SPIP-5050 μL5-50 μL(For 10 μL,10 μL extended tips)0.5 μL
SPIP-50H50 μL5-50 μL (For 200 μL tips)0.5 μL
SPIP-100100 μL10-100 μL1 μL
SPIP-200200 μL20-200 μL1 μL
SPIP-10001000 μL100-1000 μL5 μL
SPIP-50005000 μL1000-5000 μL50 μL
SPIP-1000010 mL1-10 mL100 μL
8-Channel PipetteSPIP-B1010 μL1-10 μL0.1 μL
SPIP-B20L20 μL2-20 μL (For 10 μL,10 μL extended tips)0.1 μL
SPIP-B5050 μL5-50 μL(For 10 μL, 10 μL extended tips)0.5 μL
SPIP-B100100 μL10-100 μL1 μL
SPIP-B300300 μL50-300 μL1 μL
SPIP-B10001000 μL100-1000 μL5 μL


Product Features

· Single channel: 0.1-2.5μL, 1-10μL, 2-20 μL, 5-50 μL, 10-100 μL, 20-200μL, 100-1000μL, 1000-5000μL, 1-10 mL; Multi-color range markers, 10 sizes optional;

· Multi-channel: 1-10 μL, 2-20 μL,5-50 μL, 10-100 μL , 50-300 μL, 100-1000 μL, 6 sizes optional;

· Lightweight and Ergonomic design provides excellent operating, very suitable for gripping. Light spring, press very labor-saving, help to relieve fatigue of hand joints, easy suction.

· Digital display, adjusted delivery volume clearly indicated in the large digital display on the handle.

· Fully made of high strength material. Anti-strengthening corrosion, alcohol disinfection; Enhanced anti UV linearity, UV sterilization;

· Different colors are used to identify pressing handles, making it easier to select pipettes of required specifications;

· Well-compatible with most of the pipette tips on the market;

· The pipette is equipped with Servicebio pipette tips to ensure good air tightness and accurate pipetting volume;

· Each Servicebio pipette is calibrated according to EN/ISO8655 standard, with strict quality control to ensure that each pipette is a high-quality product!

Pipette Operation

Forward technique pipetting (low density liquids) :

1. Press the push button to the first STOP;

2. Slowly release the button to the ready position to complete the aspiration of the liquid;

3. Deliver the liquid by gently depressing the push button to the first STOP. After a delay of about one second, continue to depress the push button all the way to the second STOP. This action will empty the tip.

4. Release the push button to the ready position. If necessary, change the tip and continue pipetting.

Reverse Technique Pipetting (for high viscosity or volatile liquids) :

1. Depress the push button all the way to the second STOP for aspirating liquid, slowly release the button to the ready postion to complete the aspiration of the liquid, aspirating more than the preset volume;

2. Press the button to the first STOP and discharge the preset volume of liquid;

3. The remaining liquid should either be discarded with the tip.

Calibration and Adjustment: Take out the Service tool and place the Service tool as shown in the figure, Turn the service tool clockwise to increase, or counterclockwise to decrease the volume. Calibrate pipettes 1-2 times per year (depending on frequency of use)

Storage and Transportation

Storage and transportation in room temperature.

Notice

1. Before liquid handling, make sure that the pipette and tips are at the same temperature, hold the pipette in an upright position while aspirating the liquid , and dip the tip under the surface of the liquid to a depth of 2~3mm. Fill and empty the tip by several times to moisten the tip nozzle before pipetting (particularly when working with high-viscosity liquids or density different from water);

2. If the pipette tip is full of liquid, do not turn the pipette upside down or lay it flat to prevent liquid from flowing into the cavity. It is recommended to use a special pipette stand when placing the pipette;

3. Make sure to use it within the volume range when pipetting;

4. If it is not in use for a long time, it is recommended to apply special maintenance oil to the sealing ring;

5. If need to disassemble, please find a professional technician for maintenance.

Videos

View this product on the manufacturer website (Servicebio) ↗

Request a quotation

Fill in the form and the Envision Sciplus team will reply with a quotation and delivery time.

Product Pipette, 1-10 μL, Pink Catalog #: SPIP-10
Sent to info@envisionsci.com