ชุดตรวจ ELISA สำหรับสปีชีส์อื่น

Human ACTH(Adrenocorticotropic Hormone) ELISA Kit

รหัสสินค้า: REA1070H

ผู้ผลิต: Reed Biotech

ขนาด: 96 T48 T

ราคา: กรุณาสอบถาม

สปีชีส์
Human
ความไว
0.45 pg/mL
ช่วงการตรวจวัด
3.91-250pg/mL
ชนิดตัวอย่าง
Serum, Plasma and Tissue homogenate and Other biological samples;

ELISA

Product Details

Product Name Human ACTH(Adrenocorticotropic Hormone) ELISA Kit Species Human
Uniprot ID Q01718 Alternative Names Corticotropin; Adrenocorticotropin
Detection method Sandwich Sensitivity 0.45 pg/mL
Standard 250pg/mL Detection Range 3.91-250pg/mL
Sample type Serum, Plasma and Tissue homogenate and Other biological samples;Sample volume:100μL
Reaction time 3.5H Research Area N/A
Test principle N/A

Technical Data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, washing technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data is provided below for reference only.

(pg/mL) OD Corrected
250.00 2.436 2.383
125.00 1.799 1.746
62.50 1.012 0.959
31.25 0.555 0.502
15.63 0.326 0.273
7.81 0.158 0.105
3.91 0.112 0.059
0.00 0.053
Precision

Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level were tested on 3 different plates, 20 replicates in each plate, respectively.

Intra-assay Precision Inter-assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean(pg/mL) 8.181 27.786 114.625 11.034 30.036 107.875
Standard deviation 0.557 1.817 4.310 0.625 1.322 3.474
C V (%) 6.81 6.54 3.76 5.66 4.40 3.22
Rate of recovery

The recovery of spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

Sample Type Range(%) Average Recovery(%)
Serum (n=8) 93-103 98
EDTA plasma (n=8) 85-95 90
Cell culture media (n=8) 86-96 91
Linear

Samples were spiked with high concentrations of target proteins and diluted with Reference Standard & Sample Diluent to produce samples with values within the range of the assay.

Serum (n=5) EDTA plasma (n=5) Cell culture media (n=5)
1:2 Range (%) 96-104 95-104 89-96
Average (%) 100 100 93
1:4 Range (%) 89-98 91-99 95-104
Average (%) 94 95 99
1:8 Range (%) 98-107 98-105 89-97
Average (%) 102 101 92
1:16 Range (%) 94-101 90-97 91-101
Average (%) 97 94 96